Net2 Plus - Door control centre/controller with PoE+-EV in plastic housing

Product information "Net2 Plus - Door control centre/controller with PoE+-EV in plastic housing"

Info - Net2 Plus is a network-based access control system. Such a system offers the possibility of centralised management, event notification and flexible control over user access authorisations. Each door control centre is part of the network, but can also work independently. It makes its own decisions and saves events.

The Net2 Plus door control centre is connected to the management computer with an RJ45 plug via a normal TCP/IP network. This greatly increases the flexibility of installation in buildings with LAN/WAN networks. The Net2 Plus door control centre also has an RS485 connection. This allows it to be connected to other Net2 Plus or Net2 Classic door control units via a CAT5 cable.

A Net2 Plus door control unit can also act as an interface to a LAN for an RS485 connection (daisy chain) of other Net2 Plus or Net2 Classic door control units so that they no longer require a TCP/IP interface.

Door control units are sold as an assembly, in a plastic housing or with a 2 A power supply in a plastic housing.

Available downloads

Manufacturer information

Paxton Deutschland GmbH

Paxton Deutschland GmbH
Westhoffstr. 128
D–48159 Münster
Germany

verkauf@paxton-gmbh.de

Properties "Net2 Plus - Door control centre/controller with PoE+-EV in plastic housing"
Compatibility: Paxton Net2
Connections: RJ45, RS485
Operating models: Cloud solution, Local installation
Power supply: 12V DC
Datasheets
Installation instructions

Oops! Your browser doesn't support PDFs!

Product data sheet control centre

Oops! Your browser doesn't support PDFs!

Product data sheet POE injector

Oops! Your browser doesn't support PDFs!

Product dimensions
Door control centre: W116mm x H25mm x L126mm
Housing: B236mm x H80mm x L320mm

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Please enter a valid email address.
Please enter a valid question.
Fields marked with * are mandatory.

There aren't any asked questions yet.

Accessories

%
Emergency battery for Net2 Controller
The 12V 7.2 AH VDS approved lead-acid backup battery is a reliable power source designed for use in critical applications . With its high capacity and VDS approval, this battery ensures optimum performance and safety for various emergency power and backup systems, including use with Paxton Net2 controllers in plastic or steel enclosures. - High capacity With a capacity of 7.2 AH, this battery provides a reliable power supply that is ideal for use in alarm systems, monitoring systems and especially for Paxton Net2 controllers. - VDS approval This battery fulfils the strict requirements of the VDS (Association of Property Insurers) and therefore guarantees the highest safety standards and quality for use in safety-critical areas. - Long service life Lead-acid technology ensures a long service life and high cycle stability, so you can rely on long-lasting and stable performance - Robust design The battery is robust and hard-wearing, making it ideal for use in demanding environments. Its robust design protects the cells from external influences and ensures safe operation. - Easy installation With standardised connections and a compact format, the battery can be easily integrated and installed in various systems without the need for special adaptations. It is optimised for both plastic and steel housings of Net2 controllers. - Environmentally friendly This lead-acid battery is recyclable and thus contributes to an environmentally conscious use by providing a sustainable solution for emergency power supply systems. The 12V 7.2 AH VDS approved lead-acid backup battery is the perfect choice for anyone looking for a reliable and powerful power source for their safety-critical systems. It is ideal for use with Paxton Net2 controllers and offers first-class performance and safety in a convenient format. Go for quality and reliability with this powerful battery!

Similar products

%
Entry - Control centre
Product information - The Entry control centre is the central interface between a door station and the door and supplies the monitors with data and power via PoE. The ports can also be used to extend the network of door stations and monitors using Entry extension switches or to connect the control centre to a Net2 system running Net2 v4.25 or higher.Installation - Entry components can be easily connected using Cat5 or standard RJ45 patch cables. Entry can also utilise an existing network infrastructure for easy installation. As power and data are supplied via PoE over the same cable, a separate power supply is not required.Operation - A visitor starts a video call via the bell button on the external door station. Access can then be granted to the visitor via the Entry Monitor with its intuitive touchscreen user interface. The indoor monitor can be used either with the handset (for private calls) or in hands-free mode.When connected to Net2, access to the building can be authorised via PIN or code entry and/or a proximity transponder.
%
Entry - Extension switch
Info - Entry is a door intercom that works both as a stand-alone system and together with the Paxton Net2 access control system, combining the intercom with the most important functions of Net2. Entry consists of 3 components that are automatically recognised during setup; the external door station, the indoor door intercom monitor and a door control unit.Entry is a plug-and-play solution that includes a range of possible door stations and is suitable for a variety of locations.The Net2 Entry control unit is the central interface between a door station and the door and supplies the monitors with data and power via PoE. The ports can also be used to extend the network of door stations and monitors using Net2 Entry extension switches or to connect the control unit to a Net2 system (running Net2 software V4.25 or higher).Installation - The Entry components can be easily connected using Cat5 or standard RJ45 patch cables. For easy installation, Entry can also utilise an existing network infrastructure. A separate power supply is not required thanks to PoE technology, as data and power are transmitted via the same cable.Operation - The visitor initiates a video call via the bell button on the door station. Access can now be granted via the internal Entry Monitor. This has an intuitive touchscreen user interface and can be used either via the handset for confidential calls or in hands-free mode.In conjunction with Net2 access control, access to the building can also be granted using a PIN code and/or proximity tag.
%
Net2 - I/O module in plastic housing
Info - The Net2 I/O module has 4 inputs and 4 outputs. It is connected directly to the Ethernet (LAN/WAN) via an RJ45 connection on the circuit board. I/O modules can therefore be distributed throughout a building according to requirements. Inputs and outputs can be controlled via the "Trigger actions" function of the Net2 software. The I/O module is available as an assembly, in a plastic housing or in a plastic/metal housing with a built-in 2 A power supply.Installation - The module's connection terminals are clearly labelled. The I/O module is equipped with the same proven terminal strips as the Net2 door control centres.Operation - The parameterisation of the inputs and outputs of the I/O module is configured using the "Trigger actions" function of the Net2 software.
%
Net2 - I/O module with, 2A-EV in plastic housing
Info - The Net2 I/O module has 4 inputs and 4 outputs. It is connected directly to the Ethernet (LAN/WAN) via an RJ45 connection on the circuit board. I/O modules can therefore be distributed throughout a building according to requirements. Inputs and outputs can be controlled via the "Trigger actions" function of the Net2 software. The I/O module is available as an assembly, in a plastic housing or in a plastic/metal housing with a built-in 2 A power supply.Installation - The module's connection terminals are clearly labelled. The I/O module is equipped with the same proven terminal strips as the Net2 door control centres.Operation - The parameterisation of the inputs and outputs of the I/O module is configured using the "Trigger actions" function of the Net2 software.
%
Net2 - I/O module, module only
Info - The Net2 I/O module has 4 inputs and 4 outputs. It is connected directly to the Ethernet (LAN/WAN) via an RJ45 connection on the circuit board. I/O modules can therefore be distributed throughout a building according to requirements. Inputs and outputs can be controlled via the "Trigger actions" function of the Net2 software. The I/O module is available as an assembly, in a plastic housing or in a plastic/metal housing with a built-in 2 A power supply.Installation - The module's connection terminals are clearly labelled. The I/O module is equipped with the same proven terminal strips as the Net2 door control centres.Operation - The parameterisation of the inputs and outputs of the I/O module is configured using the "Trigger actions" function of the Net2 software.
%
Net2 - Nano door control centre/controller with 2A-EV in plastic housing
Info - Net2 is a networked PC-controlled access control system with the advantages of centralised control, event logging and flexible control of user access options. Each door control centre is part of a network. However, it can be operated independently of other components, make its own decisions and record events.The Net2 Nano control panel uses wireless technology developed by Paxton Access to connect to the central PC running the Net2 software. Net2 Nano door control units can be used in conjunction with Net2 Classic and Net2 Plus door control units and can be integrated into existing Net2 installations. This is particularly useful in places where cabling is difficult.Door control units are available as a module (without housing), in a plastic housing or together with a 2 A power supply in a plastic housing. Net2 nano door control units cannot be installed in a metal housing, as this would interfere with the wireless connection. Net2 nano should be used with the Net2 software.Installation - There is a label on the Net2 nano door control unit on which the connections for the reader, door opener, power supply, etc. are clearly indicated by colour coding. The device has a dedicated output for an electric strike (incl. integrated diode) and a voltage-free relay output for switching any electric strike, other opening drive or electronic device. Exit buttons, door contacts, tamper switches and alarm devices can be connected.The door control centres transmit the data to the PC via the Net2Air USB interface or the Net2Air Ethernet interface. Paxton Access supplies products to determine the required wireless range at a site prior to installation. The corresponding connections are equipped with diagnostic LEDs, which are helpful for a trouble-free installation. Operation - All changes entered into the PC are transmitted to the door control centre and stored there. When a user presents a transponder to a reader, the user is identified by the door control centre and access is granted or denied accordingly.
%
Net2 Plus - Door control centre/controller in Ku housing
About - Net2 Plus is a network-based access control system. Such a system offers the possibility of centralised management, event notification and flexible control of user access authorisations. Each door control centre is part of the network, but can also work independently. It makes its own decisions and saves events.The Net2 Plus door control centre is connected to the management computer with an RJ45 plug via a normal TCP/IP network. This greatly increases the flexibility of installation in buildings with LAN/WAN networks. The Net2 Plus door control centre also has an RS485 connection. This allows it to be connected to other Net2 Plus or Net2 Classic door control units via a CAT5 cable.A Net2 Plus door control unit can also act as an interface to a LAN for an RS485 connection (daisy chain) of other Net2 Plus or Net2 Classic door control units so that they no longer require a TCP/IP interface.Door control units are sold as an assembly, in a plastic housing or with a 2 A power supply in a plastic housing. Installation - There is a label on the Net2 Plus door control unit that clearly shows the colour-coded connections for reader, power supply, etc. The door control centre has a relay with potential-free contacts and can therefore control electric strikes or other opening drives. Door and tamper contacts, exit buttons and local alarm devices can also be connected.Door control centres communicate with the PC via the standard TCP/IP protocol of a LAN network. The Net2 Plus door control centre should be assigned a fixed IP address. All settings are made in the Net2 Configuration Utility.The corresponding connections are equipped with diagnostic LEDs, which are helpful for a trouble-free installation. Terminal resistors can be switched on or off as required. External terminal resistors are not required.Operation - All changes entered in the PC are immediately transmitted to the door control centre and stored there. When a user presents a transponder to a reader, the user is identified by the door control centre and access is granted or denied as appropriate.
%
Net2 Plus - Door control centre/controller with 2A-EV in Ku housing
About - Net2 Plus is a network-based access control system. Such a system offers the possibility of centralised management, event notification and flexible control of user access authorisations. Each door control centre is part of the network, but can also work independently. It makes its own decisions and saves events.The Net2 Plus door control centre is connected to the management computer with an RJ45 plug via a normal TCP/IP network. This greatly increases the flexibility of installation in buildings with LAN/WAN networks. The Net2 Plus door control centre also has an RS485 connection. This allows it to be connected to other Net2 Plus or Net2 Classic door control units via a CAT5 cable.A Net2 Plus door control unit can also act as an interface to a LAN for an RS485 connection (daisy chain) of other Net2 Plus or Net2 Classic door control units so that they no longer require a TCP/IP interface.Door control units are sold as an assembly, in a plastic housing or with a 2 A power supply in a plastic housing. Installation - There is a label on the Net2 Plus door control unit that clearly shows the colour-coded connections for reader, power supply, etc. The door control centre has a relay with potential-free contacts and can therefore control electric strikes or other opening drives. Door and tamper contacts, exit buttons and local alarm devices can also be connected.Door control centres communicate with the PC via the standard TCP/IP protocol of a LAN network. The Net2 Plus door control centre should be assigned a fixed IP address. All settings are made in the Net2 Configuration Utility.The corresponding connections are equipped with diagnostic LEDs, which are helpful for a trouble-free installation. Terminal resistors can be switched on or off as required. External terminal resistors are not required. Operation - All changes entered in the PC are immediately transmitted to the door control centre and stored there. When a user presents a transponder to a reader, the user is identified by the door control centre and access is granted or denied as appropriate.
%
Net2 Plus - Door control centre/controller with PoE+-EV in steel housing
About - Net2 Plus is a network-based access control system. Such a system offers the possibility of centralised management, event notification and flexible control of user access authorisations. Each door control centre is part of the network, but can also work independently. It makes its own decisions and saves events.The Net2 Plus door control centre is connected to the management computer with an RJ45 plug via a normal TCP/IP network. This greatly increases the flexibility of installation in buildings with LAN/WAN networks. The Net2 Plus door control centre also has an RS485 connection. This allows it to be connected to other Net2 Plus or Net2 Classic door control units via a CAT5 cable.A Net2 Plus door control unit can also act as an interface to a LAN for an RS485 connection (daisy chain) of other Net2 Plus or Net2 Classic door control units so that they no longer require a TCP/IP interface.Door control units are sold as an assembly, in a plastic housing or with a 2 A power supply in a plastic housing. Installation - There is a label on the Net2 Plus door control unit that clearly shows the colour-coded connections for reader, power supply, etc. The door control centre has a relay with potential-free contacts and can therefore control electric strikes or other opening drives. Door and tamper contacts, exit buttons and local alarm devices can also be connected.Door control centres communicate with the PC via the standard TCP/IP protocol of a LAN network. The Net2 Plus door control centre should be assigned a fixed IP address. All settings are made in the Net2 Configuration Utility.The corresponding connections are equipped with diagnostic LEDs, which are helpful for a trouble-free installation. Terminal resistors can be switched on or off as required. External terminal resistors are not required. Operation - All changes entered in the PC are immediately transmitted to the door control centre and stored there. When a user presents a transponder to a reader, the user is identified by the door control centre and access is granted or denied as appropriate.
%
Net2 Plus - Door control centre/controller, module only
About - Net2 Plus is a network-based access control system. Such a system offers the possibility of centralised management, event notification and flexible control of user access authorisations. Each door control centre is part of the network, but can also work independently. It makes its own decisions and saves events.The Net2 Plus door control centre is connected to the management computer with an RJ45 plug via a normal TCP/IP network. This greatly increases the flexibility of installation in buildings with LAN/WAN networks. The Net2 Plus door control centre also has an RS485 connection. This allows it to be connected to other Net2 Plus or Net2 Classic door control units via a CAT5 cable.A Net2 Plus door control unit can also act as an interface to a LAN for an RS485 connection (daisy chain) of other Net2 Plus or Net2 Classic door control units so that they no longer require a TCP/IP interface.Door control units are sold as an assembly, in a plastic housing or with a 2 A power supply in a plastic housing. Installation - There is a label on the Net2 Plus door control unit that clearly shows the colour-coded connections for reader, power supply, etc. The door control centre has a relay with potential-free contacts and can therefore control electric strikes or other opening drives. Door and tamper contacts, exit buttons and local alarm devices can also be connected.Door control centres communicate with the PC via the standard TCP/IP protocol of a LAN network. The Net2 Plus door control centre should be assigned a fixed IP address. All settings are made in the Net2 Configuration Utility.The corresponding connections are equipped with diagnostic LEDs, which are helpful for a trouble-free installation. Terminal resistors can be switched on or off as required. External terminal resistors are not required. Operation - All changes entered in the PC are immediately transmitted to the door control centre and stored there. When a user presents a transponder to a reader, the user is identified by the door control centre and access is granted or denied as appropriate.
%
Paxton10 - Alarm connector
About - The Paxton10 Alarm Connector is a miniature I/O adapter for the integration of fire and intruder alarm systems into a Paxton10 system. With its compact design, the discrete circuit board fits neatly into the detector housing.Installation - The alarm connector is inserted into the housing of the fire or burglar alarm system. The Alarm Connector has two inputs for monitoring and one output for arming or disarming an intruder alarm system. The connectors are powered via a Paxton10 door or video controller. Each door or video controller supports one alarm connector.
%
Paxton10 - Single-door controller, 12V 2A PSU
About –  Paxton10 Door Controllers are the building blocks of the Paxton10 system. Each one provides control of a single door and a port to allow support up to three Paxton10 Wireless Connectors for additional functionality. A single Paxton10 system can include up to 1000 door controllers. The Paxton10 Door Controller is a network device that communicates over TCP/IP and can be integrated into an existing network infrastructure. This controller is equipped with 4 inputs; tamper, 230v fail, door contact, and RTE. An intruder alarm can be integrated using the Paxton10 Alarm Connector (010-203). Power over Ethernet (PoE) and PCB only (with or without plastic enclosure) options also available. Installation – The wiring label on the Paxton10 Door Controller clearly shows colour coded connections for the readers, power supply, lock etc. The 12v output for the lock can be used to control any door, barrier or gate. Diagnostic LED’s indicate the status of the controller and its inputs and outputs. Controllers are connected directly to the network via TCP/IP. They are automatically visible in the Paxton10 software under the devices menu. Operation – Any changes made in the Paxton10 software are immediately communicated to the door controller. When a user presents their token to the reader, the control unit identifies them and permits or denies access as appropriate.  

Customers also bought

%
Proximity reader MIFARE®, P50
Info - The Info-P series readers are suitable for Switch2 and Net2 systems. The readers are only supplied with a dark-coloured cover cap. Caps in other colours are available. These and replacement caps are available free of charge to registered installers of Paxton systems. The P-Series readers are available in four sizes.Installation - The reader connection cable is connected to the door control unit according to the colour coding. Installation is simple and can be carried out accurately.Operation - A transponder is held in the area of the reading distance. The reader forwards the read information to the door control unit. If the transponder is recognised as authorised, the green LED flashes and access is granted. The red LED flashes and access is denied if the transponder is invalid.Our P50 Mifare readers are now equipped with Genuine HID Technology®. When licensed with an activation card, the readers can read HID 125kHz proximity transponders. If required, these readers can also be activated for a Wiegand output via a separate activation card.
%
19" switch with management
This layer 2/3 switch with extensive L3 functions was specially developed for applications with high data loads, such as video over IP, video streaming also in conjunction with multicast . The compact design and reduced number of ports make this switch ideal for smaller systems or as a remote unit in a larger network. With its extensive management options, can also fulfil complex network requirements. Special features for access control Component-friendly features Extra high backplane performance for smooth transmission with full port utilisation. Jumbo frames up to 9600bytes are also supported at 100MBit/s. port security through MAC address restriction. DMS DMS (Device Management System) The switch has an integrated network monitoring and control system, which gives the user a very simple overview of the entire network. This DMS system has the following features: Graphical network overview The network topology view provides a quick overview of all switches and end devices in the network, such as IP cameras or servers, with details of the IP address, device type and name. Maps and maps can be stored as background images with which the user can quickly access specific network devices even without knowledge of the IP structure. Device search This function also allows targeted access to a specific device in larger networks. Newly added devices, such as a replaced IP camera, are displayed immediately and allow the user to access immediately without knowing the IP address. Data traffic display The data traffic can be displayed graphically per port over a time axis. Error handling and security Network diagnostics between master switch and connected end devices. Protection mechanisms such as data rate limitation allow effective protection against unauthorised access. IEEE802.3ah and IEEE802.1ag provide tools for structuring networks. Technical data General properties Supply voltage 100-240VAC, 50-60Hz Power consumption Max. 25W MTBF 25°C: 595'825h 50°C: 271'556h Operating temperature 0°C to 40°C Dimensions 220 x 134 x 44mm (WxDxH) Interfaces Copper ports 10 x 10/100/1000TX, RJ45 Fibre optic ports 2 x 100/1000, SFP or 10/100/1000TX, RJ45 (Combo) We recommend the use of our barox SFPs. The compatibility of our devices with SFPs from other manufacturers is not tested by us and is not guaranteed. Console ports 1 x RS232, RJ45 Network features Backplane 20 GBit/s MAC table 32k Configuration Console, Web GUI, SNMPv1, v2c and v3 PoE management Port settings Port disable/enable. Auto-negotiation 10/100/1000Mbps. Flow control disable/enable. Data rate control on each port. Max. Framesize, Power Control Port status display Display per port: speed link status, flow control status. Auto negotiation status, trunk status. Layer3 functions IPv4 and IPv6 unicast: static routing VLAN 802.1Q Tagged based VLAN, up to 255 VLAN groups, Q-in-Q, private VLAN Link Aggregation IEEE 802.3ad LACP / Static trunk, supports 18 groups of 8-port trunks or static trunk QoS Traffic classification based, Strict priority and WRR, 4-level priority for Switching - Port number - 802.1p priority- DS/TOS field in IP Packet Security SSH, SSL, 802.1X RADIUS, port security, ACL with MAC, IP, multicast and much more. User authentication with private key Multicast IGMP v1/v2/v3 snooping, up to 1024 multicast groups, source-specific multicast, IGMP proxy Topology STP, RSTP, MSTP Standards IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX/100BASE-FX IEEE 802.3z Gigabit SX/LX IEEE 802.3ab Gigabit 1000T IEEE 802.3x Flow Control and Back pressure IEEE 802.3ad Port trunk with LACP IEEE 802.1d Spanning tree protocol IEEE 802.1w Rapid spanning tree protocol IEEE 802.1s Multiple spanning tree protocol IEEE 802.1p Class ofservice IEEE 802.1Q VLAN Tagging IEEE 802.1x Port Authentication Network Control IEEE 802.1ab LLDP IEEE 802.az Energy Efficient Ethernet Types/features RY-LGS23-10G RY-19'' bracket Pair of brackets for mounting the RY-GSP23-10G in a 19" frame Included in the scope of delivery
%
Net2 - Desktop reader, USB
Info - The desktop reader is set up next to the PC. It is used to read transponders into a Net2 system and to identify transponders that have been found.Installation - Simply connect the reader to a USB port. No further cabling is required. Additional workstations can also be equipped with desktop readers. Operation - An uncoded transponder is applied to the desktop reader. This creates a new user file and the transponder number is automatically entered. The user details are entered into the file and the transponder is then issued to the user.If a transponder that has already been issued is applied to the desktop reader, the corresponding user file appears.
Compact - Relay module, 5 pieces
Info - Compact systems use a 12 V DC switching voltage as the output for a lock. This is not suitable for situations where voltage-free contacts are required to control external devices, such as shutters or 24 V locks. The control output module of the compact system is designed to be connected via this output (green/yellow wires) and to provide switched (NO/NC) de-energised contacts.Installation - The connections are colour coded to show the connections for the compact system. Simply carry out the wiring according to the label on the module.Operation - The control output can be used for switching a maximum of 40 volts DC / AC at 4 A.
%
Digital Euro Profile double knob cylinder AX - SmartIntego (Paxton) - Comfort
The Digital Cylinder AX is the most powerful cylinder we have ever had. And it is also the most user-friendly: An ergonomic yet compact knob with visual and acoustic signalling makes it easy to operate. We have also emphasised the importance of high-quality materials. This makes the AX digital cylinder robust and durable, with consistently low operating costs. Today the Digital Cylinder AX represents the state of the art. But it also harbours the future. Because it is equipped for further progress and has the technical potential for future innovations. Digital Euro Profile Double Thumbturn Cylinder AX - Comfort: Inside is firmly engaged. Doors can therefore be opened from this side without a transponder or SmartCard. Modular length Stainless steel knobs can be removed Integrated drill protection The Digital Cylinder AX - Comfort is often used in office, flat or house entrance doors . This cylinder can only be used with the Wireless Online System.
%
GatewayNode 2 for SmartIntego
The GatewayNode 2 for SmartIntego is an innovative solution for the seamless conversion of Ethernet signals into the 868 MHz frequency band. With this powerful device, you can optimise your smart home applications and ensure reliable communication between your devices. Main features: - Ethernet implementation: The GatewayNode 2 enables effective transmission of Ethernet data to the 868 MHz frequency, resulting in a stable connection and an improved range - Connection for external plug-in power supply: The device comes with the option of connecting an external plug-in power supply (POWER.SUPPLY.2) to increase the flexibility of the power supply. - Integrated antennas: Both the transmitting and receiving antennas are integrated on the router board, which simplifies installation and ensures a compact design. - Power over Ethernet (PoE) capable: Thanks to the support of the 802.3af standard, the GatewayNode 2 can be supplied with power via the Ethernet cable, eliminating the need for additional power connections.
Loading...