Product information "Net2 Pro - Software"

About - The Net2 software is designed for operation on a PC with Windows operating systems. A complete list of compatible operating systems for Net2 can be foundat here. It manages and documents up to 50,000 users and 1,000 doors. There are two versions of the software: Net2 Lite, free and ideal for the majority of sites, and Net2 Pro, with additional features for flexible and advanced access control.

Net2 Lite includes all the features required for access control, access rights management and user documentation. Additional features include unlimited free client logins, CCTV, basic functions for the integration of intruder alarm systems and location graphics.

Net2 Pro has all the features of Net2 Lite software with advanced time and attendance and timeline features, integrating time management, fire and intruder alarms with multiple alarm zones. Security locking, dual use control and card designer are useful enhancements.

Net2 site management made easy with Paxton Connect Adminpaxton Connect Admin, offers simple and flexible site management for Net2 system engineers and Net2 operators. Our new app includes five features in one smart interface, allowing you and your customers to manage multiple sites from one smartphone.

Installation - Setup and configuration are straightforward. The simple installation wizard guides you through the setup process. The control units are identified and named according to their serial number, with which each unit is labelled. Control units can also be given meaningful names. Each control unit is configured by the Net2 software as required.

Operation - Net2 operators must be added. These are users who are authorised to manage the software. There are different authorisation levels to restrict access to certain functions. Each operator must log in to the software with a user name and password. This is logged as an event.

The software is intuitive to use and even the most complex functions can be carried out easily and without training. After about two hours, you will be familiar with the operation of the software.

Available downloads

Manufacturer information

Paxton Deutschland GmbH

Paxton Deutschland GmbH
Westhoffstr. 128
D–48159 Münster
Germany

verkauf@paxton-gmbh.de

Datasheets
Integration of Net2 with a fire alarm system

Oops! Your browser doesn't support PDFs!

Using roll call and muster reports

Oops! Your browser doesn't support PDFs!

Net2 Card printing

Oops! Your browser doesn't support PDFs!

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Please enter a valid email address.
Please enter a valid question.
Fields marked with * are mandatory.

There aren't any asked questions yet.

Similar products

%
Licence for connecting a SimonsVoss locking component to Zuko Services DC
Licence for connecting a SimonsVoss locking component to Zuko Services DC The licence authorises the integration of a Simons Voss component into the system. A licence is required for each connected device. The following locking units can be licensed: Electronic cylinder Electronic fitting Electronic padlock The licence allows full use of the software functions for the respective component. The licence is device-related and non-transferable. It must be purchased separately for each individual locking unit. Only valid in conjunction with an existing installation of Zuko Services DC. The licence is valid exclusively for Simons Voss brand products.This licence is only required if the SimonsVoss hardware is not purchased from us.
%
Licence to connect a SimonsVoss locker lock to Zuko Services DC
Licence for connecting a SimonsVoss locker lock to Zuko Services DC The licence authorises the integration of a Simons Voss component into the system. A licence is required for each connected device. The following locking units can be licensed: Electronic locker lock The licence allows full use of the software functions for the respective component. The licence is device-related and non-transferable. It must be purchased separately for each individual locking unit. Only valid in conjunction with an existing installation of Zuko Services DC. The licence is valid exclusively for Simons Voss brand products.This licence is needed when the SimonsVoss hardware is not purchased from our company.
%
SmartIntego programming device
Programming device for connection to a PC/laptop via USB interface for SmartIntego locking devices. Note: Can only be operated together with the "SI.SW" configuration software. Included in the scope of delivery: SI.SMARTCD programming device, USB cable, CD-ROM with manual and USB drivers. When used with a PC/laptop, SimonsVoss SmartIntego configuration software must be used.
%
Software contract for Zuko Services DC
Software contract in in connection with the purchase and use of the middleware software Zuko Services DC for the integration of Simons Voss locking components (cylinders, fittings, padlocks, locker locks) into the access control system Paxton Net2. Scope of services of the software contract: Update service: Regular provision of software updates, including bug fixes, functional improvements and security updates. Warranty: Functional maintenance of the software within the scope of the documented specifications in conjunction with the released Net2 versions. Any defects are rectified via the update service. Support: Technical support for installers for questions regarding installation, configuration and use of the software, provided by telephone or e-mail during regular business hours. System expansion: The integration of further Simons Voss components (cylinders, fittings, padlocks, locker locks) is only possible within the framework of an existing and active software contract. Contract terms: The contract term is one year, starting from the date of licence activation. Automatic renewal by a further year in each case, unless the contract is cancelled in writing with three (3) months' notice to the end of the term. Cancellation terminates all contractual services, including update and support authorisation and the option to extend the system. The contract is object-related to the respective basic licence and is not transferable. Billing unit: Flat rate per year and software installation
%
Zuko Services DC
Zuko Services DC for the integration of Simons Voss in Paxton Net2 The software enables centralised management of locking components from the company SimonsVoss via the Paxton Net2 interface using a standardised user interface. It can be used modularly and supports both wireless online and the virtual card network. Range of functions / Features: User rights management: Centralised configuration of individual access rights per user, including time slot definition and door assignment. User administration: Creating, editing and deleting users and transponders; fast assignment of rights via central interface. Time zone management: Definition of access periods for user groups or individuals with flexible time control. Individual opening: Option for one-off door opening by authorised users - e.g.E.g. for visitors or temporary service providers. Permanent release: Time-controlled or permanent opening of doors (e.g.E.g. during office hours or for permanently authorised persons). Access times: Management and customisation of daily access times per user and door group. Whitelist function: Local backup authorisation on the end devices for offline operation - up to 250 users can be stored per locking component. Media recognition: Support for Mifare Desfire EV1, EV2, EV3 - either via UID or encrypted coding. Encryption technology: Support of own AES coding rules or use of pre-encoded cards. Alternatively UID-based authentication. Wireless online (WO) support: Real-time communication with Simons Voss components without manual updates. Changes to rights take effect immediately. Virtual Card Network (VCN): Offline-capable access control via authorisations stored on media. Changes to authorisations are updated at the next contact. The use of the middleware requires the purchase of an additional component-related licence for each Simons Voss locking unit to be connected - including cylinders, fittings, locker locks and padlocks

Customers also bought

%
Proximity reader MIFARE®, P50
Info - The Info-P series readers are suitable for Switch2 and Net2 systems. The readers are only supplied with a dark-coloured cover cap. Caps in other colours are available. These and replacement caps are available free of charge to registered installers of Paxton systems. The P-Series readers are available in four sizes.Installation - The reader connection cable is connected to the door control unit according to the colour coding. Installation is simple and can be carried out accurately.Operation - A transponder is held in the area of the reading distance. The reader forwards the read information to the door control unit. If the transponder is recognised as authorised, the green LED flashes and access is granted. The red LED flashes and access is denied if the transponder is invalid.Our P50 Mifare readers are now equipped with Genuine HID Technology®. When licensed with an activation card, the readers can read HID 125kHz proximity transponders. If required, these readers can also be activated for a Wiegand output via a separate activation card.
%
Net2 Plus - Door control centre/controller with PoE+-EV in plastic housing
Info - Net2 Plus is a network-based access control system. Such a system offers the possibility of centralised management, event notification and flexible control over user access authorisations. Each door control centre is part of the network, but can also work independently. It makes its own decisions and saves events.The Net2 Plus door control centre is connected to the management computer with an RJ45 plug via a normal TCP/IP network. This greatly increases the flexibility of installation in buildings with LAN/WAN networks. The Net2 Plus door control centre also has an RS485 connection. This allows it to be connected to other Net2 Plus or Net2 Classic door control units via a CAT5 cable.A Net2 Plus door control unit can also act as an interface to a LAN for an RS485 connection (daisy chain) of other Net2 Plus or Net2 Classic door control units so that they no longer require a TCP/IP interface.Door control units are sold as an assembly, in a plastic housing or with a 2 A power supply in a plastic housing.
%
19" switch with management
This layer 2/3 switch with extensive L3 functions was specially developed for applications with high data loads, such as video over IP, video streaming also in conjunction with multicast . The compact design and reduced number of ports make this switch ideal for smaller systems or as a remote unit in a larger network. With its extensive management options, can also fulfil complex network requirements. Special features for access control Component-friendly features Extra high backplane performance for smooth transmission with full port utilisation. Jumbo frames up to 9600bytes are also supported at 100MBit/s. port security through MAC address restriction. DMS DMS (Device Management System) The switch has an integrated network monitoring and control system, which gives the user a very simple overview of the entire network. This DMS system has the following features: Graphical network overview The network topology view provides a quick overview of all switches and end devices in the network, such as IP cameras or servers, with details of the IP address, device type and name. Maps and maps can be stored as background images with which the user can quickly access specific network devices even without knowledge of the IP structure. Device search This function also allows targeted access to a specific device in larger networks. Newly added devices, such as a replaced IP camera, are displayed immediately and allow the user to access immediately without knowing the IP address. Data traffic display The data traffic can be displayed graphically per port over a time axis. Error handling and security Network diagnostics between master switch and connected end devices. Protection mechanisms such as data rate limitation allow effective protection against unauthorised access. IEEE802.3ah and IEEE802.1ag provide tools for structuring networks. Technical data General properties Supply voltage 100-240VAC, 50-60Hz Power consumption Max. 25W MTBF 25°C: 595'825h 50°C: 271'556h Operating temperature 0°C to 40°C Dimensions 220 x 134 x 44mm (WxDxH) Interfaces Copper ports 10 x 10/100/1000TX, RJ45 Fibre optic ports 2 x 100/1000, SFP or 10/100/1000TX, RJ45 (Combo) We recommend the use of our barox SFPs. The compatibility of our devices with SFPs from other manufacturers is not tested by us and is not guaranteed. Console ports 1 x RS232, RJ45 Network features Backplane 20 GBit/s MAC table 32k Configuration Console, Web GUI, SNMPv1, v2c and v3 PoE management Port settings Port disable/enable. Auto-negotiation 10/100/1000Mbps. Flow control disable/enable. Data rate control on each port. Max. Framesize, Power Control Port status display Display per port: speed link status, flow control status. Auto negotiation status, trunk status. Layer3 functions IPv4 and IPv6 unicast: static routing VLAN 802.1Q Tagged based VLAN, up to 255 VLAN groups, Q-in-Q, private VLAN Link Aggregation IEEE 802.3ad LACP / Static trunk, supports 18 groups of 8-port trunks or static trunk QoS Traffic classification based, Strict priority and WRR, 4-level priority for Switching - Port number - 802.1p priority- DS/TOS field in IP Packet Security SSH, SSL, 802.1X RADIUS, port security, ACL with MAC, IP, multicast and much more. User authentication with private key Multicast IGMP v1/v2/v3 snooping, up to 1024 multicast groups, source-specific multicast, IGMP proxy Topology STP, RSTP, MSTP Standards IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX/100BASE-FX IEEE 802.3z Gigabit SX/LX IEEE 802.3ab Gigabit 1000T IEEE 802.3x Flow Control and Back pressure IEEE 802.3ad Port trunk with LACP IEEE 802.1d Spanning tree protocol IEEE 802.1w Rapid spanning tree protocol IEEE 802.1s Multiple spanning tree protocol IEEE 802.1p Class ofservice IEEE 802.1Q VLAN Tagging IEEE 802.1x Port Authentication Network Control IEEE 802.1ab LLDP IEEE 802.az Energy Efficient Ethernet Types/features RY-LGS23-10G RY-19'' bracket Pair of brackets for mounting the RY-GSP23-10G in a 19" frame Included in the scope of delivery
%
Net2 - Desktop reader, USB
Info - The desktop reader is set up next to the PC. It is used to read transponders into a Net2 system and to identify transponders that have been found.Installation - Simply connect the reader to a USB port. No further cabling is required. Additional workstations can also be equipped with desktop readers. Operation - An uncoded transponder is applied to the desktop reader. This creates a new user file and the transponder number is automatically entered. The user details are entered into the file and the transponder is then issued to the user.If a transponder that has already been issued is applied to the desktop reader, the corresponding user file appears.